Search
搜索
All categories
Number of views:
1000
UL & VDE CERTIFICATION 16A PCB TYPE SMART HOME RELAY
-16A contacts switching capability.
-Only impulse excitation needed, both for single and double coil.
-4KV dielectric strength between coil and contacts
-RoHS compliant
-Outline dimensions: (25 x 13 x 17) mm
-VDE Certificate NO.: 40030447
-UL Certificate NO.: E340054
Product serial number
Product description
Parameters
Download
UL & VDE Certification 16A PCB Type Smart Home Relay Details
Contact Data
Contact Form | 1B | |
Contact Material | AgSnO₂/ W+AgSnO₂ | |
Contact Resistance | Max. 50mΩ (1A 6VDC) | |
Rated Load(Resistive) | 16A 250VAC/28VDC | |
Max. Switching Voltage | 250VAC/28VDC | |
Max. Switching Current | 16A | |
Max. Switching Power | 4000VA/448W | |
Service Life | Mechnical Endurance | 1x106 OPS |
Electrical Endurance | 1x105 OPS | |
Max. Short-circuit Current | 500A/2ms |
Characteristics
Operate Time | 15ms Max. | |
Release Time | 15ms Max. | |
Insulation Resistance (500VDC) | 500MΩ Min. | |
Dielectric Strength (50/60hz,1 min) | Contact to Coil | 4000VAC |
Across Open Contacts | 1000VAC | |
Contact to contact | / | |
Surge Voltage (1 .2/50 μ s) | Contact to Coil | 20KVAC |
Creepage Distance | 8mm | |
Unit Weight | About 14g |
Environmental Data
Ambient Temperature | -40℃一+70℃ | Relative Humidity | 5%-85% RH | |
Vibration | 10-55Hz 1.5mm | Shock | 98m/s² |
Coil Data (20℃)
Coil Voltage (VDC) | Coil Resistance (Ω)±10% | Coil Power (W) | Operating Voltage (VDC) | Releasing Voltage (VDC) | Allowing Voltage (VDC) | Pulse Duration (ms) | |||
Single | Double | Single | Double | ||||||
□5 | 39.1 | 19.5/19.5 | 0.64 | 1.28 | ≤3.5 | ≤3.5 | 7.5 | ≥50 | |
□6 | 56.3 | 28.1/28.1 | ≤4.2 | ≤4.2 | 9 | ||||
□9 | 126.6 | 63.3/63.3 | ≤6.3 | ≤6.3 | 13.5 | ||||
□12 | 225 | 112.5/112.5 | ≤8.4 | ≤8.4 | 18 | ||||
□24 | 900 | 450/450 | ≤16.8 | ≤16.8 | 36 |